Calibrated photoacoustic spectrometer based on a conventional imaging system for in vitro characterization of contrast agents

Résumé

Photoacoustic (PA) imaging systems are spreading in the biomedical community, and the development of new PA contrast agents is an active area of research. However, PA contrast agents are usually characterized with spectrophotometry or uncali-brated PA imaging systems, leading to partial assessment of their PA efficiency. To enable quantitative PA spectroscopy of con-trast agents in vitro with conventional PA imaging systems, we have developed an adapted calibration method. Contrast agents in solution are injected in a dedicated non-scattering tube phantom imaged at different optical wavelengths. The calibration method uses a reference solution of cupric sulfate to simultaneously correct for the spectral energy distribution of excitation light at the tube location and perform a conversion of the tube amplitude in the image from arbitrary to spectroscopic units. The method does not require any precise alignment and provides quantitative PA spectra, even with non-uniform illumination and ultrasound sensitivity. It was implemented on a conventional imaging setup based on a tunable laser operating between 680 nm and 980 nm and a 5 MHz clinical ultrasound array. We demonstrated robust calibrated PA spectroscopy with sample volumes as low as 15 μL of known chromophores and commonly used contrast agents. The validated method will be an essential and acces-sible tool for the development of new and efficient PA contrast agents by improving their quantitative characterization.
Fichier principal
Vignette du fichier
Published_version220901.pdf (1.82 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-02509232 , version 1 (16-03-2020)
hal-02509232 , version 2 (27-04-2021)
hal-02509232 , version 3 (08-07-2022)
hal-02509232 , version 4 (01-09-2022)

Licence

Paternité

Identifiants

Citer

Théotim Lucas, Mitradeep Sarkar, Yoann Atlas, Clément Linger, Gilles Renault, et al.. Calibrated photoacoustic spectrometer based on a conventional imaging system for in vitro characterization of contrast agents. Sensors, 2022, 22 (17), pp.6543. ⟨10.3390/s22176543⟩. ⟨hal-02509232v4⟩
334 Consultations
139 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More