Résumé
The present studies aim at characterizing selectively prepared ions by infrared spectroscopy. The spectra are obtained by monitoring InfraRed MultiPhoton Dissociation (IRMPD) for which the use of an intense laser source is required. IR Free Electron Laser offering both high peak power and wide tunability are ideally suited for this particular spectroscopy. Coupling with a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer (FT-ICR-MS) gives access to a wide range of chemical species and allows for the study of reaction intermediates.
Format du dépôt | Fichier |
---|---|
Type de dépôt | Poster de conférence |
Résumé |
en
The present studies aim at characterizing selectively prepared ions by infrared spectroscopy. The spectra are obtained by monitoring InfraRed MultiPhoton Dissociation (IRMPD) for which the use of an intense laser source is required. IR Free Electron Laser offering both high peak power and wide tunability are ideally suited for this particular spectroscopy. Coupling with a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer (FT-ICR-MS) gives access to a wide range of chemical species and allows for the study of reaction intermediates.
|
Titre |
en
Vibrational spectroscopy of selectively prepared gas phase ions by coupling an FT-ICR-MS with a Free Electron Laser
|
Auteur(s) |
Joël Lemaire
1, 2
, Luke Macaleese
1
, Catherine Kapota
3, 2
, Gilles Ohanessian
3
, Pierre Boissel
1
, Jean-Michel Ortega
2
, Philippe Maıtre
1
1
LCPO -
Laboratoire de Chimie Physique D'Orsay
( 1175 )
- Bâtiments 349/350 avenue Georges CLEMENCEAU 91405 ORSAY CEDEX
- France
2
LURE -
Laboratoire pour l'utilisation du rayonnement électromagnétique
( 502 )
- bat. 209 D BP 34 91898 ORSAY CEDEX
- France
3
DCMR -
Laboratoire des mécanismes réactionnels
( 1168 )
- aile 1 2ème etg Route de Saclay 91128 PALAISEAU CEDEX
- France
|
Vulgarisation |
Non
|
Audience |
Internationale
|
Comité de lecture |
Oui
|
Actes |
Non
|
Langue du document |
Anglais
|
Titre du congrès |
16th International Mass Spectrometry Conference (IMSC 2003)
|
Date début congrès |
2003-08-31
|
Date fin congrès |
2003-09-05
|
Ville |
Edimbourg
|
Pays |
Royaume-Uni
|
Domaine(s) |
|
Origine :
Fichiers produits par l'(les) auteur(s)
Loading...