Critical assessment of the moisture distribution in existing building walls
Évaluation critique de la répartition de l'humidité dans les murs de bâtiments existants
Résumé
Current environmental issues focus on the energy performance of existing buildings. Thus, the problem of the moisture content within a wall is of capital importance. However, its assessment in existing buildings is difficult to obtain. Therefore, the inverse problem approach is proposed. In this article the moisture distribution within the existing building wall is presented through the spatial variation. Then, the coefficients of polynomial representation are estimated using the temperature measurements. The case study of the existing building wall is considered. The obtained results and issues raised by this approach are discussed.
Parmi les enjeux environnementaux actuels figure l'amélioration de la performance énergétique des bâtiments existants. Ainsi, le problème du taux d'humidité à l'intérieur des murs est d'une importance capitale. Cependant, son évaluation dans les bâtiments est difficile. Par conséquent, l'approche par résolution du problème inverse est proposée. Dans cet article, la distribution d'humidité dans un mur de bâtiment est présentée à travers une variation spatiale par décomposition polynomiale. Ensuite, les coefficients de la représentation polynomiale sont estimés à partir des mesures de température. L'application à un mur de bâtiment ancien est considérée. Les résultats obtenus et les problèmes soulevés par cette approche sont discutés.
Origine | Fichiers produits par l'(les) auteur(s) |
---|