A New combined transient extraction method coupled with WO 3 gas sensors for polluting gases classification - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Sensor Review Année : 2021

A New combined transient extraction method coupled with WO 3 gas sensors for polluting gases classification

Résumé

Purpose-this paper dealt with the classification improvement of pollutant using WO3 gases sensors. To evaluate the discrimination capacity, some experiments were achieved using three gases: ozone, ethanol, acetone and a mixture of ozone and ethanol via four WO3 sensors. Design/methodology/approach-To improve the classification accuracy and enhance selectivity, some combined features that were configured through the Principal Component Analysis (PCA) were used. First, evaluate the discrimination capacity; some experiments were performed using three gases: ozone, ethanol, acetone and a mixture of ozone and ethanol, via four WO3 sensors. To this end, three features that are derivate, integral and the time corresponding to the peak derivate have been extracted from each transient sensor response according to four WO3 gas sensors used. Then these extracted parameters were used in a combined array. Findings-The results show that the proposed feature extraction method could extract robust information. The Extreme Learning Machine (ELM) was used to identify the studied gases. In addition, ELM was compared with the Support Vector Machine (SVM). The experimental results prove the superiority of the combined features method in our E-nose application since this method achieves the highest classification rate of 90% using the ELM and 93.03% using the SVM based on Radial Basis Kernel Function SVM-RBF. Originality/value-combined features have been configured from transient response to improve the classification accuracy. The achieved results show that the proposed feature extraction method could extract robust information. The Extreme Learning Machine ELM and Support Vector Machine SVM were used to identify the studied gases.
Fichier principal
Vignette du fichier
A New combined transient extraction method coupled with WO3 gas sensors 21.pdf (809.35 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03618788 , version 1 (24-03-2022)

Licence

Paternité - Pas d'utilisation commerciale

Identifiants

  • HAL Id : hal-03618788 , version 1

Citer

Khalifa Aguir. A New combined transient extraction method coupled with WO 3 gas sensors for polluting gases classification. Sensor Review, 2021. ⟨hal-03618788⟩
39 Consultations
57 Téléchargements

Partager

Gmail Facebook X LinkedIn More