Performance prediction of 3 meter semi-anechoic chamber between 30 and 200MHz taking into account the near field effect - Archive ouverte HAL Accéder directement au contenu
Communication Dans Un Congrès Année : 2006

Performance prediction of 3 meter semi-anechoic chamber between 30 and 200MHz taking into account the near field effect

Résumé

This paper addresses EMI (ElectroMagnetic Interference) chamber performance in the frequency range between 30 and 200MHz, which is where chambers exhibit their deficiencies. The difference between attenuation in an open area test site (OATS), called Normalized Site Attenuation (NSA) and this same measure in the test chamber gives the performances. The European EN50147-2 (1) and American ANSI C63-4 standards (2) authorize a maximum deviation of  4 dB. Numerical modelling enables us to identify performances and thus optimise the chamber. In this work, we propose a whole new chamber modelling with a boundary condition taking into account the reflectivity of ferrite tile. Also we focus on antenna modelling because of the significant mutual coupling effect in this frequency range, unlike other previous works (3,4,5) which consider electrically small antennas.

Domaines

Electronique
Fichier principal
Vignette du fichier
emc2006.pdf (587.67 Ko) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte
Loading...

Dates et versions

hal-02166932 , version 1 (27-06-2019)

Identifiants

  • HAL Id : hal-02166932 , version 1

Citer

Gwenaël Dun, Jean-François Rosnarho, François Le Pennec, Philippe Gelin. Performance prediction of 3 meter semi-anechoic chamber between 30 and 200MHz taking into account the near field effect. EMC Europe 2006, Sep 2006, Barcelone, Spain. ⟨hal-02166932⟩