A comprehensive theoretical comparison of proton imaging set-ups in terms of spatial resolution

Résumé

We present a comprehensive analytical comparison of four types of proton imaging set-ups and, to this end, develop a mathematical framework to calculate the width of the uncertainty envelope around the most likely proton path depending on set-up geometry, detector properties, and proton beam parameters. As a figure of merit for the spatial resolution achievable with each set-up, we use the frequency f 10% at which the modular transfer function of a density step decreases below 10%. We verify the analytical results with Monte Carlo simulations. We find that set-ups which track the angle and position of individual protons in front of and behind the phantom would yield an average spatial resolution of 0.3-0.35 lp/mm assuming realistic geometric parameters (i.e., 30-40 cm distance between detector and phantom, 1520 cm phantom thickness). For set-ups combining pencil beam scanning with either a position sensitive detector, e.g., an X-ray flat panel, or with a position insensitive detector, e.g., a range telescope, we find an average spatial resolution of about 0.1 lp/mm for an 8 mm FWHM beam spot size. The pixel information improves the spatial resolution by less than 10%. In both set-up types, performance can be significantly improved by reducing the pencil beam size down to 2 mm FWHM. In this case, the achievable spatial resolution reaches about 0.25 lp/mm. Our results show that imaging set-ups combining double scattering with a pixel detector can provide sufficient spatial resolution only under very stringent conditions and are not ideally suited for computed tomography applications. We further propose a region-ofinterest method for set-ups with a pixel detector to filter out protons which have undergone nuclear reactions and discuss the impact of tracker detector uncertainties on the most likely path.
Fichier non déposé

Dates et versions

hal-02048546 , version 1 (25-02-2019)

Identifiants

  • HAL Id : hal-02048546 , version 1

Citer

Nils Krah. A comprehensive theoretical comparison of proton imaging set-ups in terms of spatial resolution. Proton Imaging Workshop Lyon 2018, Jun 2018, Lyon, France. ⟨hal-02048546⟩
82 Consultations
0 Téléchargements

Partager

Gmail Facebook X LinkedIn More