Optimal low-stator-frequency avoidance strategy to improve the performances of induction machine sensorless drives - Archive ouverte HAL Accéder directement au contenu
Communication Dans Un Congrès Année : 2015

Optimal low-stator-frequency avoidance strategy to improve the performances of induction machine sensorless drives

Résumé

This paper focuses on speed-sensorless drive of induction machine without signal injection. To ensure good performances of the speed observer without the disruptive effects of signal injection, it is possible to avoid the unobservable working points which lead to poor speed observation. To do so, the existing methods aim at avoiding the low stator frequencies. They are nonetheless difficult to use for real applications since they lack flexibility and do not take into account some industrial constraints. The approach presented in this paper consists in formulating all the working constraints in order to build a cost function. By minimizing this cost function, the proposed optimal avoidance strategy is more flexible and can be applied for any industrial application.
Fichier non déposé

Dates et versions

hal-01984856 , version 1 (17-01-2019)

Identifiants

Citer

Gaétan Lefebvre, Vincent Le Digarcher, Jean-Yves Gauthier, Alaa Hijazi, Xuefang Lin-Shi. Optimal low-stator-frequency avoidance strategy to improve the performances of induction machine sensorless drives. 2015 IEEE SLED, Jun 2015, Sydney, Australia. ⟨10.1109/SLED.2015.7339256⟩. ⟨hal-01984856⟩