Statistical design of in silico experiments for the robustness analysis of electrophysiologic response simulators

Résumé

To assess the risk of Torsade de Pointes, the CiPA initiative has proposed to test in silico models able to reconstruct electrophysiologic responses and analyze mechanistic causes of specific toxicological events such as TdP. One example of such simulators is the O’Hara Rudy’s model, used herein as a benchmark model. Such in silico models are composed of a large number of biological parameters. Their values are never fully known and they are generally estimated with a substantial uncertainty. So, what happens if the values of some parameters are wrong? Can we still trust the simulated responses? In this application context, our objective is to firstly identify the critical modeling parameters. To reduce the computation time, we propose a statistical approach suited to the screening of model parameters. Our approach relies on a Placket-Burman design of numerical assays. 79 models parameters have been tested and only 80 numerical experiments were carried out. The action potential response was split up into five phases and three statistics (duration, AUC and amplitude) were computed for each phase. Accordingly, 15 response variables were analyzed. A Pareto analysis is finally used to rank the most critical parameters. Results show that all the tested modeling factors have the same order of effect on the global response. In other terms, no parameter can be neglected. Two parameters appear as more critical than the other ones: the stimulus current and the initial temperature of the cell. The effects of all the parameters on each of the five beating phase are also estimated and ranked. This study analyzes the sensitivity of the simulated potential action response with respect to uncertainty on 79 modeling parameters. All of them have significant effects on at least one part of the response, which emphasizes the relevance to accurately estimate them to trust simulations. As a consequence, another crucial question is worth asking and deals with the model identifiability, i.e. the possibility to learn the true values of the model parameters after obtaining an infinite (theoretical identifiability) or a finite (practical identifiability) number of in vitro observations.
Fichier principal
Vignette du fichier
Poster_SPS_inSilico-Cardio_v2.pdf (1.14 Mo) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-01669909 , version 1 (21-12-2017)

Identifiants

  • HAL Id : hal-01669909 , version 1

Citer

Romain Duponnois, Théo Docquier, Thomas Aiguier, Thierry Bastogne. Statistical design of in silico experiments for the robustness analysis of electrophysiologic response simulators. Safety Pharmacology Society 2017 Annual Meeting, SPS 2017, Dec 2017, Berlin, Germany. ⟨hal-01669909⟩
410 Consultations
213 Téléchargements

Partager

More