Weld pool surface temperature measurement from polarization state of thermal emission - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Quantitative InfraRed Thermography Journal Année : 2016

Weld pool surface temperature measurement from polarization state of thermal emission

Résumé

This paper presents a passive polarimetry method using a division of aperture optical device in order to measure the temperature distribution at the weld pool surface. Thermal emission from a hot liquid metal was investigated at a near-infrared wavelength corresponding to a blind spectral window of a helium plasma generated during gas tungsten arc welding process. The refractive index of liquid metal and the surface radiance are deduced from the polarisation state of thermal emissions. Based upon the knowledge of both characteristics, the temperature distribution can be calculated.
Fichier principal
Vignette du fichier
coniglio2016.pdf (3.19 Mo) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-01318648 , version 1 (21-12-2017)

Identifiants

Citer

Nicolas Coniglio, Alexandre Mathieu, Olivier Aubreton, Christophe Stolz. Weld pool surface temperature measurement from polarization state of thermal emission. Quantitative InfraRed Thermography Journal, 2016, 13 (1), pp.83-93. ⟨10.1080/17686733.2015.1102475⟩. ⟨hal-01318648⟩
246 Consultations
477 Téléchargements

Altmetric

Partager

Gmail Mastodon Facebook X LinkedIn More