Fault Tolerant Dual-Motor Drives: Sizing of Power Electronic

Abstract

This paper analyzes two dual-motor fault-tolerant topologies. The first one supplies independently both machines while the second one connects them in series for reducing the number of transistors. For a given DC-link voltage, the converter component sizing is based on the peak current obtained in the normal and degraded modes.
Fichier principal
Vignette du fichier
EPE_TiagoJoseDOSSANTOSMORAES.pdf (1.02 Mo) Télécharger le fichier
Origin Files produced by the author(s)
Loading...

Dates and versions

hal-01241420 , version 1 (21-03-2016)

Identifiers

  • HAL Id : hal-01241420 , version 1
  • ENSAM : http://hdl.handle.net/10985/10479

Cite

Tiago José dos Santos Moraes, Ngac Ky Nguyen, Fabien Meinguet, Eric Semail. Fault Tolerant Dual-Motor Drives: Sizing of Power Electronic. EPE 2015, Sep 2015, Genève, Switzerland. ⟨hal-01241420⟩