Résumé

This paper presents a calibrated measurement technique that enables phase and magnitude measurements of wideband multisines. This study is based on the use of a large-signal network analyzer (LSNA) performing harmonic sub-sampling and a fine frequency grid (20 MHz) comb generator calibrated using a high-frequency 50-GHz equivalent-time sampling scope. This comb generator is used as a harmonic phase reference generator for the calibration of the LSNA. The research reported here is applied to L-band multisine measurements, but it can be extended to higher microwave frequencies. The motivation of this study is to measure the multipactor phenomena effect in output RF multiplexers of satellite payloads.

Fichier non déposé

Dates et versions

hal-00660576 , version 1 (17-01-2012)

Identifiants

Citer

Mohamed El Yaagoubi, Guillaume Neveux, Denis Barataud, Tibault Reveyrand, Jean-Michel Nebus, et al.. Time-domain calibrated measurements of wideband multisines using a Large-Signal Network Analyzer. IEEE Transactions on Microwave Theory and Techniques, 2008, 56 (5), pp.1180-1192. ⟨10.1109/TMTT.2008.921645⟩. ⟨hal-00660576⟩