Maximum Working Volume Evaluation in a Non-Canonical Reverberation Chamber
Résumé
This paper presents a procedure for evaluating the performance of reverberation chambers, by approximating the maximum working volume in a given configuration. The evaluation of this volume is based on the geometrical and physical constraints, e.g., the ones related to the internal E-field distribution recommended by standards. The importance of the present work is related to the development of a non-canonical reverberation chamber configuration, whose excitation is carried out by transmission lines, instead of antennas plus paddles.
Domaines
Energie électrique
Fichier principal
IEEE-T-Mag_45-3_03-2009_1646_Avila_MaximumWorkingVolume.pdf (121.59 Ko)
Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte