Maximum Working Volume Evaluation in a Non-Canonical Reverberation Chamber
Résumé
This paper presents a procedure for evaluating the
performance of reverberation chambers, by approximating the
maximum working volume in a given configuration. The evaluation of
this volume is based on the geometrical and physical constraints, like
the ones related to the internal E-field distribution recommended by
standards. The importance of the present work is related to the
development of a non-canonical reverberation chamber configuration,
whose excitation is carried out by transmission lines, instead of
antennas plus paddles.