Validation of a novel Real-LIFE test protocol on two log wood stoves
Résumé
The use of log wood stoves is common in residential homes and are tested in a type test procedure following EN 16510-1:2022 at optimal combustion condition. Since this does not represent real-life operation, a novel test protocol was developed and validated using two different log wood stoves. The new test protocol includes the ignition phase (two batches) at natural draught, followed by three batches at nominal load, two batches at partial load and one final batch at overload. Typical emission parameters such as carbon monoxide (CO), nitrogen oxides (NOX), organic gaseous carbon (OGC) emissions were recorded as well as TPM emissions in the hot undiluted flue gas. This study shows that it is challenging to get similar emission results for the same stove in different laboratories even when using the same fuel and well-defined test protocol, differences in results are due to measurement uncertainty, differences in appliance operations and not following exactly the defined Real-LIFE test protocol. Coefficients of variation for TPM, CO, OGC and NOX were 17.8 %, 20.1 %, 30.6 % and 8.7 %, respectively for stove A and 32.7 %, 13.9 %, 19.6 % and 10.0 %, respectively for stove B based on two to three repetitions per lab. The novel test protocol showed that combustion appliances may behave differently in different combustion phases, and this emphasizes the importance of measuring different combustion conditions in official testing to ensure that the appliances work properly in the field and that the measured emissions cover the whole operating range.
Domaines
| Origine | Publication financée par une institution |
|---|---|
| Licence |