Résumé

Purpose This study addresses the critical issue of evaluating the risk of rupture of unruptured intracranial aneurysms (UIAs) through the assessment of the mechanical properties of the aneurysm wall. To achieve this, an original approach based on the development of an in vivo deformation device prototype (DDP) of the vascular wall is proposed. The DDP operates by pulsing a physiological fluid onto the vascular wall and measuring the resulting deformation using spectral photon counting computed tomography (SPCCT) imaging. Methods In this preliminary study conducted on a rabbit animal model, an aneurysm was induced on the carotid artery, fol‑ lowed by deformation of the aneurysm sac wall using the DDP. The change in luminal volume of the aneurysm sac induced by the deformation of the vascular wall was then quantified. Results The initial experimental results demonstrated an increase in the luminal volume of the aneurysm sac in relation to the increased flow rate of the fluid pulsed by the DDP onto the arterial wall. Measurement of the pressure generated by the DDP in relation to the different flow rate values imposed by the pulsation system revealed experimental values of the same order of magnitude as dynamic blood pressure. Furthermore, theoretical pressure values on the deformed area, calculated using Euler’s theorem, appeared to be correlated with experimental pressure measurements. Conclusion This equivalence between theory and experiment is a key element in the use of the DDP for estimating the mechanical properties of the vascular wall, particularly for the use of finite element models to characterise the stress state of the deformed vascular wall. This preliminary work thus presents a novel, innovative, and promising approach for the evalu‑ ation and management of the risk of rupture of unruptured intracranial aneurysms.

Dates et versions

hal-04806363 , version 1 (27-11-2024)

Identifiants

Citer

Guillaume Plet, Jolan Raviol, Jean-Baptiste Langlois, Salim Si-Mohamed, Hélène Magoariec, et al.. Correction: An In vivo Pilot Study to Estimate the Swelling of the Aneurysm Wall Rabbit Model Generated with Pulsed Fluid Against the Aneurysm Wall. Annals of Biomedical Engineering, 2024, ⟨10.1007/s10439-024-03642-6⟩. ⟨hal-04806363⟩
0 Consultations
0 Téléchargements

Altmetric

Partager

More