High-sensitivity AC-charge detection with a MHz-frequency fluxonium qubit - Archive ouverte HAL
Pré-Publication, Document De Travail (Preprint/Prepublication) Année : 2023

High-sensitivity AC-charge detection with a MHz-frequency fluxonium qubit

Baldo-Luis Najera-Santos
  • Fonction : Auteur
  • PersonId : 1414866
  • IdRef : 280220308
Rémi Rousseau
  • Fonction : Auteur
  • PersonId : 1272619
Kyrylo Gerashchenko
  • Fonction : Auteur
  • PersonId : 1272620
Himanshu Patange
  • Fonction : Auteur
  • PersonId : 1272621
Angela Riva
  • Fonction : Auteur
  • PersonId : 1272622
Tristan Briant
  • Fonction : Auteur
  • PersonId : 1142015
Antoine Heidmann
José Palomo
  • Fonction : Auteur
  • PersonId : 1312478
Alain Sarlette
Thibaut Jacqmin
Samuel Deléglise

Résumé

Owing to their strong dipole moment and long coherence times, superconducting qubits have demonstrated remarkable success in hybrid quantum circuits. However, most qubit architectures are limited to the GHz frequency range, severely constraining the class of systems they can interact with. The fluxonium qubit, on the other hand, can be biased to very low frequency while being manipulated and read out with standard microwave techniques. Here, we design and operate a heavy fluxonium with an unprecedentedly low transition frequency of 1.8 MHz. We demonstrate resolved sideband cooling of the ``hot'' qubit transition with a final ground state population of 97.7 %, corresponding to an effective temperature of 23 µK. We further demonstrate coherent manipulation with coherence times T1=34 µs, T2*=39 µs, and single-shot readout of the qubit state. Importantly, by directly addressing the qubit transition with a capacitively coupled waveguide, we showcase its high sensitivity to a radio-frequency field. Through cyclic qubit preparation and interrogation, we transform this low-frequency fluxonium qubit into a frequency-resolved charge sensor. This method results in a charge sensitivity of 33 µe/sqrt(Hz), or an energy sensitivity (in joules per hertz) of 2.8 hbar. This method rivals state-of-the-art transport-based devices, while maintaining inherent insensitivity to DC charge noise. The high charge sensitivity combined with large capacitive shunt unlocks new avenues for exploring quantum phenomena in the 1--10 MHz range, such as the strong-coupling regime with a resonant macroscopic mechanical resonator.
Fichier principal
Vignette du fichier
main.pdf (4.31 Mo) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-04777888 , version 1 (25-07-2023)
hal-04777888 , version 2 (12-11-2024)

Identifiants

Citer

Baldo-Luis Najera-Santos, Rémi Rousseau, Kyrylo Gerashchenko, Himanshu Patange, Angela Riva, et al.. High-sensitivity AC-charge detection with a MHz-frequency fluxonium qubit. 2023. ⟨hal-04777888v1⟩
205 Consultations
91 Téléchargements

Altmetric

Partager

More