Power Quality Analysis of Six Phase Indirect Matrix Converter Based on Multi Phase Generator - Archive ouverte HAL
Communication Dans Un Congrès Année : 2023

Power Quality Analysis of Six Phase Indirect Matrix Converter Based on Multi Phase Generator

Résumé

Nowadays, multiphase machine drives are considered in many applications, especially for medium and highpower applications. This paper focuses on the topology of the six to three phase (hexaphase) indirect matrix converter (IMC). The matrix converter (MC) is designed based on twelve bidirectional switches for the rectifier stage and six single switches for the inverter stage. It is interfaced to a high-performance, fault-tolerant multiphase permanent magnet synchronous generator (PMSG) on one side and to the grid on the other side. In the literature, the most common MCs are of the three-phase type and papers on multiple input converters (N>3) are not common. This paper deals with all possible configurations of SVM that can be deduced in a hexaphase MC to determine the modulation indexes and then to assess the VTR (Voltage Transfer Ratio). Simulations are performed on a pure inductive load and THD analysis are performed on the input currents of the MC to show the impact of the studied configurations on the system.

Dates et versions

hal-04582546 , version 1 (22-05-2024)

Identifiants

Citer

Chabi Sanni, Augustin Mpanda, Ahmed El Hajjaji. Power Quality Analysis of Six Phase Indirect Matrix Converter Based on Multi Phase Generator. 21thInternational Conference on Renewable Energies and Power Quality (ICREPQ’23), May 2023, Madrid, Spain. pp.575-582, ⟨10.24084/REPQJ21.403⟩. ⟨hal-04582546⟩