Improved reproducibility for myocardial ASL: Impact of physiological and acquisition parameters - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Magnetic Resonance in Medicine Année : 2023

Improved reproducibility for myocardial ASL: Impact of physiological and acquisition parameters

Maša Božić‐iven
Qian Tao
Iain Pierce
George Thornton
Christian Nitsche
Thomas A Treibel
Sebastian Weingärtner

Résumé

Purpose To investigate and mitigate the influence of physiological and acquisition‐related parameters on myocardial blood flow (MBF) measurements obtained with myocardial Arterial Spin Labeling (myoASL). Methods A Flow‐sensitive Alternating Inversion Recovery (FAIR) myoASL sequence with bSSFP and spoiled GRE (spGRE) readout is investigated for MBF quantification. Bloch‐equation simulations and phantom experiments were performed to evaluate how variations in acquisition flip angle (FA), acquisition matrix size (AMS), heart rate (HR) and blood relaxation time () affect quantification of myoASL‐MBF. In vivo myoASL‐images were acquired in nine healthy subjects. A corrected MBF quantification approach was proposed based on subject‐specific values and, for spGRE imaging, subtracting an additional saturation‐prepared baseline from the original baseline signal. Results Simulated and phantom experiments showed a strong dependence on AMS and FA (>0.73), which was eliminated in simulations and alleviated in phantom experiments using the proposed saturation‐baseline correction in spGRE. Only a very mild HR dependence (>0.59) was observed which was reduced when calculating MBF with individual . For corrected spGRE, in vivo mean global spGRE‐MBF ranged from 0.54 to 2.59 mL/g/min and was in agreement with previously reported values. Compared to uncorrected spGRE, the intra‐subject variability within a measurement (0.60 mL/g/min), between measurements (0.45 mL/g/min), as well as the inter‐subject variability (1.29 mL/g/min) were improved by up to 40% and were comparable with conventional bSSFP. Conclusion Our results show that physiological and acquisition‐related factors can lead to spurious changes in myoASL‐MBF if not accounted for. Using individual and a saturation‐baseline can reduce these variations in spGRE and improve reproducibility of FAIR‐myoASL against acquisition parameters.
Fichier principal
Vignette du fichier
Magnetic_Resonance_in_Med_2023_Bo_i_Iven.pdf (3.53 Mo) Télécharger le fichier
Origine : Publication financée par une institution
Licence : CC BY - Paternité

Dates et versions

hal-04296309 , version 1 (20-11-2023)

Licence

Paternité

Identifiants

Citer

Maša Božić‐iven, Stanislas Rapacchi, Qian Tao, Iain Pierce, George Thornton, et al.. Improved reproducibility for myocardial ASL: Impact of physiological and acquisition parameters. Magnetic Resonance in Medicine, 2023, 91 (1), pp.118-132. ⟨10.1002/mrm.29834⟩. ⟨hal-04296309⟩
13 Consultations
4 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More