Texture Parameters Measured by UHF-MRI and CT Scan Provide Information on Bone Quality in Addition to BMD: A Biomechanical Ex Vivo Study - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Diagnostics Année : 2022

Texture Parameters Measured by UHF-MRI and CT Scan Provide Information on Bone Quality in Addition to BMD: A Biomechanical Ex Vivo Study

Cyprien Fabre
  • Fonction : Auteur
Vanessa Pauly
  • Fonction : Auteur
Maud Creze
Enrico Soldati
Pierre Champsaur
  • Fonction : Auteur
Daphne Guenoun
  • Fonction : Auteur

Résumé

The current definition of osteoporosis includes alteration of bone quality. The assessment of bone quality is improved by the development of new texture analysis softwares. Our objectives were to assess if proximal femoral trabecular bone texture measured in Ultra high field (UHF) 7 Tesla MRI and CT scan were related to biomechanical parameters, and if the combination of texture parameters and areal bone mineral density (aBMD) measured by dual-energy X-ray absorptiometry provided a better prediction of femoral failure than aBMD alone. The aBMD of 16 proximal femur ends from eight cadavers were investigated. Nineteen textural parameters were computed in three regions or volumes of interest for each specimen on UHF MRI and CT scan. Then, the corresponding failure load and failure stress were calculated thanks to mechanical compression test. aBMD was not correlated to failure load (R2 = 0.206) and stress (R2 = 0.153). The failure load was significantly correlated with ten parameters in the greater trochanter using UHF MRI, and with one parameter in the neck and the greater trochanter using CT scan. Eight parameters in the greater trochanter using UHF MRI combined with aBMD improved the failure load prediction, and seven parameters improved the failure stress prediction. Our results suggest that textural parameters provide additional information on the fracture risk of the proximal femur when aBMD is not contributive.
Fichier principal
Vignette du fichier
diagnostics-12-03143.pdf (2.5 Mo) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte
Licence : CC BY - Paternité

Dates et versions

hal-04250805 , version 1 (07-11-2023)

Licence

Paternité

Identifiants

Citer

Paul Knoepflin, Martine Pithioux, David Bendahan, François Poullain, Thomas Le Corroller, et al.. Texture Parameters Measured by UHF-MRI and CT Scan Provide Information on Bone Quality in Addition to BMD: A Biomechanical Ex Vivo Study. Diagnostics, 2022, 12 (12), pp.3143. ⟨10.3390/diagnostics12123143⟩. ⟨hal-04250805⟩
37 Consultations
6 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More