In response to prolonged depolarizing current steps, different classes of neurons display specific firing characteristics (i.e. excitability class), such as a regular train of action potentials with more or less adaptation, delayed responses, or bursting. In general, one or more specific ionic transmembrane currents underlie the different firing patterns. Here we sought to investigate the influence of artificial sodium-like (Na channels) and slow potassium-like (KM channels) voltage-gated channels conductances on firing patterns and transition to depolarization block (DB) in Dentate Gyrus granule cells with dynamic clamp - a computer-controlled real-time closed-loop electrophysiological technique, which allows to couple mathematical models simulated in a computer with biological cells. Our findings indicate that the addition of extra Na/KM channels significantly affects the firing rate of low frequency cells, but not in high frequency cells. Moreover, we have observed that 44 percent of recorded cells exhibited what we have called a “flipping” behavior. This means that these cells were able to overcome the DB and generate trains of action potentials at higher current injections steps. We have
develop a unified mathematical model of flipping cells to explain this phenomenon. Based on our computational model, we conclude that the appearance of flipping is linked to the number of states for the sodium channel of the model.