Resynchronization of sequential measurements using the Maximally-Coherent Reference technique
Résumé
Remote sensing of a physical field generated by a small number of sources is limited by the size of the available
array of sensors and by the array density. These limitations may lead to asynchronously measuring the field
by sequentially moving a small prototype array around its facets, however at the cost of losing the phase
between every array position. Re-synchronization using references, i.e. fixed sensors, can be used for phase
retrieval, given that these references are of a number that is at least equal to the stochastic dimension of the
field, and are not inter-correlated to the degree that hinder them from spanning the source signals’ subspace.
However, when the number of references largely exceeds the number of sources, the reference cross spectral
matrix becomes ill-conditioned leading to the irrelevance of the least squares solution (LSS). Although the
truncated singular value decomposition (TSVD) was successfully applied in the literature to solve this problem,
its validity is restricted only to the case of scalar noise on the references. It is also very hard to set a threshold, for
truncation, among the singular values when the references cross-spectral matrix is well-conditioned due to high
noise levels. In this paper, a solution based on finding a set of virtual references that is maximally correlated
with the field measurements, named the Maximally-Coherent Reference Technique (MCR), is proposed for
re-synchronization. The method is validated by numerical simulations, and its results are compared to those of
the LSS and the TSVD when employed for the same purpose.
Origine | Fichiers produits par l'(les) auteur(s) |
---|