Design and Optimization of Gas Sensor Testing Chamber - Archive ouverte HAL
Communication Dans Un Congrès Année : 2018

Design and Optimization of Gas Sensor Testing Chamber

Résumé

It is important to size and optimize the chamber in which gas sensors are tested. Indeed, the amplitude, as well as the response and recovery times are very dependent on the testing chamber. In this study, we show that by optimizing the design and reducing the volume of the testing chamber, the responses of metal oxide microsensors are highly enhanced and faster, and therefore closer to the real answers of the sensor.
Fichier principal
Vignette du fichier
78012 ALLSENSORS 2018 Fatima Revised.pdf (481.99 Ko) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03942498 , version 1 (25-01-2024)

Identifiants

  • HAL Id : hal-03942498 , version 1

Citer

Fatima Ezahra Annanouch, Nicolas Morati, Virginie Martini, Tomas Fiorido, Khalifa Aguir, et al.. Design and Optimization of Gas Sensor Testing Chamber. 3rd International Conference on Advances in Sensors, Actuators, Metering and Sensing (ALLSENSORS 2018), Mar 2018, ROME, Italy. pp.15-17. ⟨hal-03942498⟩
37 Consultations
51 Téléchargements

Partager

More