In October 2012, the Ge?oazur TF laboratory in OCA has been reorganized to improve signal distribution stability. In particular we have implemented a new time scale TA(OCA) based on H-maser T4Science. The H-maser frequency is steered with an HROG-10 microphase stepper. The correction applied is computed every day taking into account the frequency of the free running maser and the actual time difference between TA(OCA) and UTC(OP). The main idea is to keep the time difference between our local time scale TA(OCA) and UTC below 50 ns, in order to time tag the SLR laser pulses and to have an error below 1 mm for distance measurement between satellite and laser station.
Fichier non déposé

Dates et versions

hal-03744036 , version 1 (02-08-2022)

Identifiants

Citer

Myrtille Laas-Bourez, Etienne Samain, Clément Courde, Daniele Rovera, Michel Abgrall, et al.. Remote steering of OCA local time scale using UTC(OP). 2014 European Frequency and Time Forum (EFTF), Jun 2014, Neuchatel, Switzerland. pp.472-474, ⟨10.1109/EFTF.2014.7331538⟩. ⟨hal-03744036⟩