Outcome of Patients with Early Repolarization Pattern and Syncope
Résumé
Background
Syncope in patients with an early repolarization (ER) pattern presents a challenge for clinicians as it has been identified as an indicator of a higher risk of life-threatening ventricular arrhythmias (VAs).
Objectives
This study aimed to analyze the outcome of patients with an ER pattern and syncope and to evaluate the factors predictive of VAs.
Methods
Over a period of 5 years, we enrolled 143 patients with an ER pattern and syncope in a multicenter prospective registry.
Results
After the initial examinations, 97 patients (67.8%) were implanted with a device allowing electrocardiogram monitoring, including 84 (58.7%) with an implantable loop recorder. During a mean follow-up period of 68 ± 34 months, we documented 16 arrhythmias presumably responsible for syncope (5 VAs, 10 bradycardias, and 1 supraventricular tachycardia). Additionally, recurrent syncope not associated with electrocardiogram documentation occurred in 16 patients (11.2%). The cause of syncope was identified in 23 of 97 patients with a monitoring device (23.8%). The 5-year incidence of VAs and arrhythmic events presumably responsible for syncope was 4.9% and 11.0%, respectively. Patients who developed VAs showed no prodromes or specific triggers at the time of syncope. Neither the presence of a family history of sudden cardiac death nor the previously reported high-risk electrocardiographic parameters differed between patients with and without VAs.
Conclusion
VAs occurred in 4.9% of patients with an ER pattern and syncope. Device implantation based on detailed history taking seems to be a reasonable strategy. Previously reported high-risk electrocardiographic patterns did not identify patients with VAs.
Origine | Fichiers produits par l'(les) auteur(s) |
---|