Adherence measurements and corrosion resistance in primer/hot-dip galvanized steel systems
Résumé
This paper focuses on the adherence during ageing of a primer (made of polyester resins crosslinked with melamine) applied onto hot-dip galvanized (HDG) steel for coil coating application and its influence on corrosion protection. A chromium-free surface treatment, composed of fluorotitanic acid, phosphoric acid, manganese phosphate, and vinylphenol was applied on the HDG steel to obtain high corrosion resistance and high adherence of a polyester and melamine primer. The influence of the manganese phosphate on the corrosion and adherence was investigated. To measure the adherence between the metal and the primer, a three-point flexure test was set up. The adherence was then linked with corrosion resistance during ageing, using electrochemical impedance spectroscopy.
Origine : Fichiers produits par l'(les) auteur(s)