Vibration and luminosity frequency analysis of the SuperKEKB collider - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Nucl.Instrum.Meth.A Année : 2022

Vibration and luminosity frequency analysis of the SuperKEKB collider

Résumé

The SuperKEKB collider has entered the physics production phase with the aim to reach its target luminosity of 6×1035 cm2s−1. Vibrations of the accelerator elements, especially around the Interaction Point (IP), could limit the performance of the collider. Since 2018, a 24-hour monitoring system of vibrations has been put in place on both sides of the Belle II detector. Measurements and analyses of the spectral components of these vibrations and of the transfer function of the mechanical supports are presented, along with measurements of luminosity spectra from the LumiBelle2 detectors, showing good agreement in spectral peak frequencies for several of the vibration sources.
Fichier principal
Vignette du fichier
S016890022101010X.pdf (22.36 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03520514 , version 1 (08-01-2024)

Licence

Paternité - Pas d'utilisation commerciale

Identifiants

Citer

Maurizio Serluca, Gael Balik, Laurent Brunetti, Benjamin Aimard, Agnes Dominjon, et al.. Vibration and luminosity frequency analysis of the SuperKEKB collider. Nucl.Instrum.Meth.A, 2022, 1025, pp.166123. ⟨10.1016/j.nima.2021.166123⟩. ⟨hal-03520514⟩