Sizing Equations for a Square Voltage Pulse Power Supply for Dielectric Barrier Discharges - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue IEEE Transactions on Power Electronics Année : 2021

Sizing Equations for a Square Voltage Pulse Power Supply for Dielectric Barrier Discharges

Résumé

This work presents an analysis of the full-bridge voltage inverter widely used to supply dielectric barrier discharges. The main contribution of this work is the deduction of the analytical equations for the delivered power, peak voltage and duration of the discharge as a function of the DC input voltage and of the switching frequency, but also, as a function of the parasitic elements of the transformer and the parameters of the DBD load. To date, these equations are not found in the literature and are useful to design a power converter complying with specifications derived from plasma process requirements. The state plane is used to understand the different sub-intervals taking place in an entire switching period. The equations are verified using a simple example of design, which implementation accurately obeys the sizing equations, and provide the expected performances.

Dates et versions

hal-03408249 , version 1 (29-10-2021)

Identifiants

Citer

Camilo Sanabria, David Florez, Hubert Piquet, Rafael Diez. Sizing Equations for a Square Voltage Pulse Power Supply for Dielectric Barrier Discharges. IEEE Transactions on Power Electronics, 2021, ⟨10.1109/TPEL.2021.3122934⟩. ⟨hal-03408249⟩
33 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More