Influence of balloon design, plaque material composition, and balloon sizing on acute post angioplasty outcomes: An implicit finite element analysis - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue International Journal for Numerical Methods in Biomedical Engineering Année : 2021

Influence of balloon design, plaque material composition, and balloon sizing on acute post angioplasty outcomes: An implicit finite element analysis

Résumé

In this work we propose a generic modeling approach for simulating percutaneous transluminal angioplasty (PTA) endovascular treatment, and evaluating the influence of balloon design, plaque composition, and balloon sizing on acute post-procedural outcomes right after PTA, without stent implantation. Clinically-used PTA balloons were classified into two categories according to their compliance characteristics, and were modeled correspondingly. Self-defined elastoplastic constitutive laws were implemented within the plaque and artery models, after calibration based on experimental and clinical data. Finite element method (FEM) implicit solver was used to simulate balloon inflation and deflation. Besides balloon profile at max inflation, results are mainly assessed in terms of the elastic recoil ratio (ERR) and lumen gain ratio (LGR) obtained immediately after PTA. No variations in ERR nor LGR values were detected when the balloon design changed, despite the differences observed in their profile at max inflation. Moreover, LGR and ERR inversely varied with the augmentation of calcification level within the plaque (-11% vs. +4% respectively, from fully lipidic to fully calcified plaque). Furthermore, results showed a direct correlation between balloon sizing and LGR and ERR, with noticeably higher rates of change for LGR (+18% and +2% for LGR and ERR respectively for a calcified plaque and a balloon pressure increasing from 10 to 14 atm). However a larger LGR comes with a higher risk of arterial rupture. This proposed methodology opens the way for evaluation of angioplasty balloon selections towards clinical procedure optimization.
Fichier principal
Vignette du fichier
Helou et al-2021-Influence of balloon design, plaque material composition, and balloon sizing on.pdf (2.2 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03268327 , version 1 (01-07-2021)

Identifiants

Citer

Bernard Helou, Aline Bel-Brunon, Claire Dupont, Wenfeng Ye, Claudio Silvestro, et al.. Influence of balloon design, plaque material composition, and balloon sizing on acute post angioplasty outcomes: An implicit finite element analysis. International Journal for Numerical Methods in Biomedical Engineering, 2021, 37 (8), pp.e03499. ⟨10.1002/cnm.3499⟩. ⟨hal-03268327⟩
71 Consultations
183 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More