Multicentric evaluation of BioFire FilmArray Pneumonia Panel for rapid bacteriological documentation of pneumonia - Archive ouverte HAL
Article Dans Une Revue Clinical Microbiology and Infection Année : 2021

Multicentric evaluation of BioFire FilmArray Pneumonia Panel for rapid bacteriological documentation of pneumonia

Julien Loubinoux
  • Fonction : Auteur
  • PersonId : 787781
  • IdRef : 060326115
Michael Levy

Résumé

OBJECTIVES: To evaluate performances of the rapid multiplex PCR assay BioFire FilmArray Pneumonia Panel (FA-PP) for detection of bacterial pathogens and antibiotic resistance genes in sputum, endotracheal aspirate (ETA) and bronchoalveolar lavage (BAL) specimens. METHODS: This prospective observational study was conducted in 11 French university hospitals (July to December 2018) and assessed performance of FA-PP by comparison with routine conventional methods. RESULTS: A total of 515 respiratory specimens were studied, including 58 sputa, 217 ETA and 240 BAL. The FA-PP detected at least one pathogen in 384 specimens, yielding an overall positivity rate of 74.6% (384/515). Of them, 353 (68.5%) specimens were positive for typical bacteria while eight atypical bacteria and 42 resistance genes were found. While identifying most bacterial pathogens isolated by culture (374/396, 94.4%), the FA-PP detected 294 additional species in 37.7% (194/515) of specimens. The FA-PP demonstrated positive percentage agreement and negative percentage agreement values of 94.4% (95% CI 91.7%-96.5%) and 96.0% (95% CI 95.5%-96.4%), respectively, when compared with culture. Of FA-PP false-negative results, 67.6% (46/68) corresponded to bacterial species not included in the panel. At the same semi-quantification level (in DNA copies/mL for FA-PP versus in CFU/mL for culture), the concordance rate was 43.4% (142/327) for culture-positive specimens with FA-PP reporting higher semi-quantification of ≥1 log(10) in 48.6% (159/327) of cases. Interestingly, 90.1% of detected bacteria with ≥10(6) DNA copies/mL grew significantly in culture. CONCLUSIONS: FA-PP is a simple and rapid molecular test that could complement routine conventional methods for improvement of diagnosis accuracy of pneumonia.
Fichier principal
Vignette du fichier
S1198743X20307102.pdf (734.95 Ko) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03102222 , version 1 (16-10-2023)

Licence

Identifiants

Citer

Nabil Gastli, Julien Loubinoux, Matthieu Daragon, Jean-Philippe Lavigne, Pierre Saint-Sardos, et al.. Multicentric evaluation of BioFire FilmArray Pneumonia Panel for rapid bacteriological documentation of pneumonia. Clinical Microbiology and Infection, 2021, 27 (9), pp.1308-1314. ⟨10.1016/j.cmi.2020.11.014⟩. ⟨hal-03102222⟩
176 Consultations
92 Téléchargements

Altmetric

Partager

More