A temperature-controlled cryogen free cryostat integrated with transceiver-mode superconducting coil for high-resolution magnetic resonance imaging. - Archive ouverte HAL
Article Dans Une Revue Review of Scientific Instruments Année : 2020

A temperature-controlled cryogen free cryostat integrated with transceiver-mode superconducting coil for high-resolution magnetic resonance imaging.

Isabelle Saniour
  • Fonction : Auteur
Gilles Authelet
  • Fonction : Auteur
Bertrand Baudouy
  • Fonction : Auteur
Rose-Marie Dubuisson
  • Fonction : Auteur
Laurène Jourdain
  • Fonction : Auteur
Georges Willoquet
  • Fonction : Auteur
Jean-Christophe Ginefri
  • Fonction : Auteur
Marie Poirier-Quinot

Résumé

Small-sized High Temperature Superconducting (HTS) radiofrequency coils are used in a number of micro-magnetic resonance imaging applications and demonstrate a high detection sensitivity that improves the signal-to-noise ratio. However, the use of HTS coils could be limited by the rarity of cryostats that are suitable for the MR environment. This study presents a magnetic resonance (MR)-compatible and easily operated cryogen-free cryostat based on the pulse tube cryocooler technology for the cooling and monitoring of HTS coils below the temperature of liquid nitrogen. This cryostat features a real-time temperature control function that allows the precise frequency adjustment of the HTS coil. The influence of the temperature on the electrical properties, resonance frequency (f0), and quality factor (Q) of the HTS coil was investigated. Temperature control is obtained with an accuracy of over 0.55 K from 60 K to 86 K, and the sensitivity of the system, extracted from the frequency measurement from 60 K to 75 K, is of about 2 kHz/K, allowing a fine retuning (within few Hz, compared to 10 kHz bandwidth) in good agreement with experimental requirements. We demonstrated that the cryostat, which is mainly composed of non-magnetic materials, does not perturb the electromagnetic field in any way. MR images of a 10 × 10 × 15 mm3 liquid phantom were acquired using the HTS coil as a transceiver with a spatial resolution of 100 × 100 × 300 µm3 in less than 20 min under experimental conditions at 1.5 T.

Domaines

Imagerie
Fichier non déposé

Dates et versions

hal-03024545 , version 1 (25-11-2020)

Identifiants

Citer

Isabelle Saniour, Gilles Authelet, Bertrand Baudouy, Rose-Marie Dubuisson, Laurène Jourdain, et al.. A temperature-controlled cryogen free cryostat integrated with transceiver-mode superconducting coil for high-resolution magnetic resonance imaging.. Review of Scientific Instruments, 2020, 91 (5), pp.055106. ⟨10.1063/1.5143107⟩. ⟨hal-03024545⟩
39 Consultations
0 Téléchargements

Altmetric

Partager

More