The Fault Tolerant Control Design of an Intensified Heat-Exchanger/Reactor Using a Two-Layer, Multiple-Model Structure - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Sensors Année : 2020

The Fault Tolerant Control Design of an Intensified Heat-Exchanger/Reactor Using a Two-Layer, Multiple-Model Structure

Résumé

The heat-exchanger/reactor (HEX reactor) is a kind of plug-flow chemical reactor which combines high heat transfer ability with good chemical performances. It was designed under the popular trend of process intensification in chemical engineering. Previous studies have investigated its characteristics and developed its nominal model. This paper is concerned with its fault tolerant control (FTC) applications. To avoid the difficulties and nonlinearities of this HEX reactor under chemical reactions, a two-layer, multiple-model structure is proposed for designing the FTC scheme. The first layer focuses on representing the nonlinear system with a bank of local linear models while the second layer uses model banks for approaching faulty situations. Model banks are achieved by system identification, and the corresponding controller banks are designed using model predictive control (MPC). The unscented Kalman filter (UKF) is introduced to estimate the states and form the fault detection and isolation (FDI) section. Finally, the FTC simulation and validation results are presented. The idea of a two-layer, multiple-model structure presents a general framework for FTC design of complex and highly nonlinear systems, such as the HEX reactor, whose mathematical model has been created. It implements the design process in an unusual way and is also worth trying on other cases.

Domaines

Automatique
Fichier principal
Vignette du fichier
sensors-20-04888-v2最终版.pdf (1.48 Mo) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte
Loading...

Dates et versions

hal-02934913 , version 1 (09-09-2020)

Identifiants

Citer

Menglin He, Zetao Li, Boutaib Dahhou, Michel Cabassud. The Fault Tolerant Control Design of an Intensified Heat-Exchanger/Reactor Using a Two-Layer, Multiple-Model Structure. Sensors, 2020, 20 (17), pp.4888. ⟨10.3390/s20174888⟩. ⟨hal-02934913⟩
60 Consultations
50 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More