Personal monitor glass badge: Theoretical dosemeter response calculated with the Monte Carlo transport code MCNPX - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue RADIATION PROTECTION DOSIMETRY Année : 2011

Personal monitor glass badge: Theoretical dosemeter response calculated with the Monte Carlo transport code MCNPX

Résumé

This paper describes the results of the simulation of a radiophotoluminescent (RPL) dosemeter with the Monte Carlo transport code MCNPX. The aim of this study is to calculate the response with MCNPX of the RPL dosemeter in terms of equivalent doses Hp (0.07) and Hp(10) using X-ray photon radiation qualities N series, together with S-Cs and S-Co nuclide radiation qualities, specified in ISO 4037-1. After comparison with reference values versus experimental results, the deviation of the theoretical responses of the RPL dosemeter proved to be lower than 5 % for reference values and lower than 10 % for experimental results. This good correlation validates the model over the energy range studied. © The Author 2011. Published by Oxford University Press. All rights reserved.
Fichier non déposé

Dates et versions

hal-02924810 , version 1 (28-08-2020)

Identifiants

Citer

N. Hocine, L. Donadille, C. Huet, C. Itié, I. Clairand. Personal monitor glass badge: Theoretical dosemeter response calculated with the Monte Carlo transport code MCNPX. RADIATION PROTECTION DOSIMETRY, 2011, 144, pp.231--233. ⟨10.1093/rpd/ncr009⟩. ⟨hal-02924810⟩

Collections

IRSN
7 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More