How Different Are Manometric, Gravimetric, and Automated Volumetric BMP Results?

Corrado Amodeo
  • Fonction : Auteur
  • PersonId : 1042558
Sasha D Hafner
  • Fonction : Auteur
Ruben Teixeira Franco
Paul Moretti
  • Fonction : Auteur
  • PersonId : 1061441
Rémy Bayard
Pierre Buffière

Résumé

The objectives of this study were to: (1) quantify differences in biochemical methane potential (BMP) measured using three measurement methods, including two popular methods (a commercial automated system (AMPTS II) and manual manometric) and one newer method (gravimetric), and (2) assess the importance of the mixing position in the measurement sequence. Powdered microcrystalline cellulose was used as the substrate in simultaneous tests. All methods gave similar results (<8% difference in the mean BMP) and were reasonably accurate (recovery of 80-86% of the theoretical maximum BMP). Manometric BMP values were consistently lower than gravimetric by 4-5%. Precision was lower for the automated method (relative standard deviation (RSD) of about 7%) than for the manual methods (RSD about 1-3%). Mixing after biogas measurement resulted in 3% higher BMP for both manual methods than mixing before, due to the lower measured CH 4 production from blanks. This effect may be linked to a fraction of CH 4 that remains dissolved or even as attached bubbles, and suggests that mixing before measurement is preferable. The automated volumetric and gravimetric methods (mode 2) gave very similar mean BMP values (1% different). However, kinetic analysis showed that methane production was faster with the automated volumetric method. This could come from an error in the estimation of the CH 4 production rate for the automated method, or an increase in the degradation rate due to better mixing. Both automatic volumetric and manual gravimetric measurements met current validation criteria for mean cellulose BMP, but the RSD from the automated system exceeded the limit.
Fichier principal
Vignette du fichier
How different are manometric gravimetric.pdf (2.38 Mo) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte
Loading...

Dates et versions

hal-02887804 , version 1 (02-07-2020)

Identifiants

Citer

Corrado Amodeo, Sasha D Hafner, Ruben Teixeira Franco, Hassen Benbelkacem, Paul Moretti, et al.. How Different Are Manometric, Gravimetric, and Automated Volumetric BMP Results?. Water, 2020, ⟨10.3390/w12061839⟩. ⟨hal-02887804⟩
101 Consultations
174 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More