Urine cell cycle arrest biomarkers distinguish poorly between transient and persistent AKI in early septic shock: a prospective, multicenter study - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Critical Care Année : 2020

Urine cell cycle arrest biomarkers distinguish poorly between transient and persistent AKI in early septic shock: a prospective, multicenter study

Résumé

Background: The urine biomarkers tissue inhibitor of metalloproteinases-2 (TIMP-2) and insulin-like growth factor-binding protein 7 (IGFBP7) have been validated for predicting and stratifying AKI. In this study, we analyzed the utility of these biomarkers for distinguishing between transient and persistent AKI in the early phase of septic shock. Methods: We performed a prospective, multicenter study in 11 French ICUs. Patients presenting septic shock, with the development of AKI within the first 6 h, were included. Urine [TIMP-2]*[IGFBP7] was determined at inclusion (0 h), 6 h, 12 h, and 24 h. AKI was considered transient if it resolved within 3 days. Discriminative power was evaluated by receiver operating characteristic (ROC) curve analysis. Results: We included 184 patients, within a median [IQR] time of 1.0 [0.0-3.0] h after norepinephrine (NE) initiation; 100 (54%) patients presented transient and 84 (46%) presented persistent AKI. Median [IQR] baseline urine [TIMP-2]*[IGFBP7] was higher in the persistent AKI group (2.21 [0.81-4.90] (ng/ml)2/1000) than in the transient AKI group (0.75 [0.20-2.12] (ng/ml)2/1000; p < 0.001). Baseline urine [TIMP-2]*[IGFBP7] was poorly discriminant, with an AUROC [95% CI] of 0.67 [0.59-0.73]. The clinical prediction model combining baseline serum creatinine concentration, baseline urine output, baseline NE dose, and baseline extrarenal SOFA performed well for the prediction of persistent AKI, with an AUROC [95% CI] of 0.81 [0.74-0.86]. The addition of urine [TIMP-2]*[IGFBP7] to this model did not improve the predictive performance. Conclusions: Urine [TIMP-2]*[IGFBP7] measurements in the early phase of septic shock discriminate poorly between transient and persistent AKI and do not improve clinical prediction over that achieved with the usual variables.
Fichier principal
Vignette du fichier
2020 Titeca-Beauport et al., Urine Cell.pdf (34.28 Mo) Télécharger le fichier
s13054-020-03205-w.pdf (195.84 Ko) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-02767652 , version 1 (16-07-2020)

Licence

Identifiants

Citer

Dimitri Titeca-Beauport, Delphine Daubin, Ly van Vong, Guillaume Belliard, Cédric Bruel, et al.. Urine cell cycle arrest biomarkers distinguish poorly between transient and persistent AKI in early septic shock: a prospective, multicenter study. Critical Care, 2020, 24 (1), pp.280. ⟨10.1186/s13054-020-02984-6⟩. ⟨hal-02767652⟩
90 Consultations
12 Téléchargements

Altmetric

Partager

Gmail Mastodon Facebook X LinkedIn More