Performance and commissioning of HAPDs in the Aerogel RICH counter - Archive ouverte HAL Accéder directement au contenu
Communication Dans Un Congrès Année : 2020

Performance and commissioning of HAPDs in the Aerogel RICH counter

Masanobu Yonenaga
  • Fonction : Auteur
Ichiro Adachi
  • Fonction : Auteur
Rok Dolenec
  • Fonction : Auteur
Koki Hataya
  • Fonction : Auteur
Toru Iijima
  • Fonction : Auteur
Shiori Kakimoto
  • Fonction : Auteur
Hidekazu Kakuno
  • Fonction : Auteur
Hideyuki Kawai
  • Fonction : Auteur
Takeo Kawasaki
  • Fonction : Auteur
Haruki Kindo
  • Fonction : Auteur
Takashi Kohriki
  • Fonction : Auteur
Tomoyuki Konno
  • Fonction : Auteur
Samo Korpar
  • Fonction : Auteur
Peter Križan
  • Fonction : Auteur
Tetsuro Kumita
  • Fonction : Auteur
Yun-Tsung Lai
  • Fonction : Auteur
Masahiro Machida
  • Fonction : Auteur
Manca Mrvar
  • Fonction : Auteur
Shohei Nishida
  • Fonction : Auteur
Kouta Noguchi
  • Fonction : Auteur
Kazuya Ogawa
  • Fonction : Auteur
Satoru Ogawa
  • Fonction : Auteur
Rok Pestotnik
  • Fonction : Auteur
Luka Šantelj
  • Fonction : Auteur
Masayoshi Shoji
  • Fonction : Auteur
Takayuki Sumiyoshi
  • Fonction : Auteur
Makoto Tabata
  • Fonction : Auteur
Sachi Tamechika
  • Fonction : Auteur
Morihito Yoshizawa
  • Fonction : Auteur
Yosuke Yusa
  • Fonction : Auteur

Résumé

The Belle II Aerogel Ring Imaging Cherenkov (ARICH) counter uses the angular distribution of Cherenkov photons emitted in silica aerogel to discriminate between charged pions and kaons. The Hybrid Avalanche Photo Detector (HAPD) is used as the photo-sensor, and is clearly the most critical component of the detector. HAPDs were installed into ARICH in July 2017, and ARICH was installed in the Belle II spectrometer in the end of 2017. During the Belle II beam commissioning in spring 2018, the performance of HAPDs was evaluated through measurements of the offset value, noise level and pulse height. Long term stability of the signal-to-noise ratio and the fraction of dead channel was also monitored. The signal-to-noise ratio exceeded 6, and the fraction of dead channels was less than 1%. The results of the performance evaluation and of the commissioning showed that the ARICH counter fulfills the requirements.
Fichier non déposé

Dates et versions

hal-02475361 , version 1 (12-02-2020)

Identifiants

Citer

Masanobu Yonenaga, Ichiro Adachi, Leonid Burmistrov, Francois Le Diberder, Rok Dolenec, et al.. Performance and commissioning of HAPDs in the Aerogel RICH counter. 10th Workshop on Ring Imaging Cherenkov Detectors, Jul 2018, Moscow, Russia. pp.162264, ⟨10.1016/j.nima.2019.06.005⟩. ⟨hal-02475361⟩
28 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Mastodon Facebook X LinkedIn More