Optimal sizing of distributed generation in gas/electricity/heat supply networks - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Energy Année : 2018

Optimal sizing of distributed generation in gas/electricity/heat supply networks

Résumé

Multi-energy supply systems are expected to play an important role in smart grids. Today's energy supply systems are large nodes networks, and different types of energy are needed at each node to satisfy the different energy demands. These different types of energy can then be converted to each other through specific devices. How to decide the ratings of these devices at each node to make the system cost-effective is addressed in this paper. The focus is set on a gas/electricity/heat hybrid network. A hydrogen storage system (fuel cell, electrolyzer, and tanks) is used as electricity storage system, a combined heat and power device is used to produce heat and electric power, etc. A mixed integer linear programming algorithm is used to determine the optimal operation schedule of the system, where the goal is to minimize shed load. A genetic algorithm is also used to search for the best size of each component, where the goal is to minimize the total investment costs. In order to resist to contingency events, betweenness centrality (describing the relative importance of each node) is then used to find the worst case under contingency events. This worst case scenario is used to research about the influence of contingencies on the sizing results. At last, two cases (modified 13-node network and IEEE 30 + Gas 20 + Heat 14 nodes system) are tested using the proposed sizing method. The results show that the renewable energy location, investment cost of components, and the structure of the whole system influence the sizing results. When the installed capacity of photovoltaic panels is reduced by 50%, the capacity of the electrolyzer decreases by 3%, the capacity for the hydrogen tanks increases by 2%; when the investment cost of the fuel cell and electrolyzer decreases by 50%, the capacity of photovoltaic increases by 14%, the electrolyzer increases by 13%, and hydrogen tanks increase by 2%. After considering the worst case contingency event, for case I, the capacity of photovoltaic and fuel cell increase by 12% and 11%, and the electrolyzer increases by 34%; for case II, the capacity of photovoltaic and fuel cell increase by 8% and 11%, and the electrolyzer increases by 57%.
Fichier principal
Vignette du fichier
cf688fea-a442-4084-b353-5555c8715a26-author.pdf (2.37 Mo) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-02131089 , version 1 (16-05-2019)

Identifiants

  • HAL Id : hal-02131089 , version 1

Citer

Bei Li, Robin Roche, Damien Paire, Abdellatif Miraoui. Optimal sizing of distributed generation in gas/electricity/heat supply networks. Energy, 2018, 151, pp.675 - 688. ⟨hal-02131089⟩
51 Consultations
258 Téléchargements

Partager

Gmail Mastodon Facebook X LinkedIn More