AC Losses of a Grid-Connected Superconducting Wind Turbine Generator - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue IEEE Transactions on Applied Superconductivity Année : 2013

AC Losses of a Grid-Connected Superconducting Wind Turbine Generator

Résumé

We present a numerical method to estimate the steady-state AC losses of a superconducting wind turbine generator connected to the grid through its AC/DC/AC converter. We use a multiscale simulation with unidirectional couplings between a lumped-parameter wind energy conversion system model, a finite element machine model, and a finite element HTS tape model. The estimation include effects linked to the generator space harmonics, the exciter control, and the AC/DC/AC converter PWM and control. As the superconducting coil is made of several thousand of HTS tapes, we evaluate AC losses for a fraction of them and we interpolate the results to the others. The steady-state AC losses of a 10 MW class generator are estimated to be under 60 W.
Fichier non déposé

Dates et versions

hal-01756385 , version 1 (02-04-2018)

Identifiants

Citer

Loic Queval, H. Ohsaki. AC Losses of a Grid-Connected Superconducting Wind Turbine Generator. IEEE Transactions on Applied Superconductivity, 2013, 23 (3), pp.5201905 - 5201905. ⟨10.1109/TASC.2013.2251252⟩. ⟨hal-01756385⟩