Stiffness Control of Pneumatic Actuators to Simulate Human Behavior on Medical Haptic Simulators - Archive ouverte HAL
Communication Dans Un Congrès Année : 2016

Stiffness Control of Pneumatic Actuators to Simulate Human Behavior on Medical Haptic Simulators

Résumé

In order to increase the realism of medical simulators, haptic interfaces could be used to simulate the patient’s body behavior. It is especially interesting to reproduce the stiffness of different soft tissues with corresponding haptic behaviors. In this paper, two control laws, impedance control and back-stepping associated with a closed-loop stiffness tuning, are introduced and applied to a pneumatic actuator. Both controllers have been obtained by using the A-T transform which is suitable to model the behavior of a pneumatic system, in a strict-feedback form. Both control laws allow to tune the system stiffness. A comparison of their performances is presented, based on experimental results.
Fichier principal
Vignette du fichier
root.pdf (1.68 Mo) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-01333383 , version 1 (22-01-2019)

Identifiants

Citer

Nicolas Herzig, Richard Moreau, Arnaud Lelevé, Minh Tu Pham. Stiffness Control of Pneumatic Actuators to Simulate Human Behavior on Medical Haptic Simulators. 2016 IEEE International Conference on Advanced Intelligent Mechatronics (AIM), IEEE, Jul 2016, Banff, Canada. pp.1591-1597, ⟨10.1109/AIM.2016.7576997⟩. ⟨hal-01333383⟩
203 Consultations
192 Téléchargements

Altmetric

Partager