Communication Dans Un Congrès Année : 2012

Background Offset and Gain Calibration for Time-Interleaved ADC Using Digital Sinusoidal Calibration Signal

Résumé

This paper presents background offset and gain calibration for time-interleaved analog-to-digital converter (TIADC). The calibration technique depends on detecting the offset and the amplitude of a calibration signal. The detection is based on a simple algorithm performed in the digital part. A digital sinusoidal wave is needed to implement the calibration technique. The calibration technique behaviors are theoretically analysed and verified by simulations. A 12-bit, 4-channel, 800 MS/s TIADC is used as an example.

Fichier principal
Vignette du fichier
Khalil2012.pdf (371.09 Ko) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)
Licence

Dates et versions

hal-01282407 , version 1 (07-10-2022)

Licence

Identifiants

Citer

Raouf Khalil, Marie-Minerve Louërat, Roger Petigny, Hugo Gicquel. Background Offset and Gain Calibration for Time-Interleaved ADC Using Digital Sinusoidal Calibration Signal. The International Conference on Synthesis, Modeling, Analysis and Simulation Methods and Applications to Circuit Design (SMACD) 2012, Sep 2012, Seville, Spain. pp.273-276, ⟨10.1109/SMACD.2012.6339392⟩. ⟨hal-01282407⟩