Time-Reversed Excitation of Reveberation Chambers: Improving Efficiency and Reliability in the Generation of Radiated Stress

Résumé

The ability of reverberation chambers to generate high-intensity field levels from relatively low-power input signals is reexamined for the case of time-reversed signals, proving that they lead to a higher efficiency. Moreover, the strong statistical spread typical of time-harmonic excitations can be dramatically reduced, thus improving the reliability of radiative tests, while limiting the need for a large number of independent realizations. The two excitation schemes are compared when forcing their respective input signals to display the same peak instantaneous power. Experimental results are provided, supporting the conclusions of our theoretical analysis.

Fichier principal
Vignette du fichier
TEMC2015-RCefficiency-PeakPower_final.pdf (430.62 Ko) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)
Licence
Loading...

Dates et versions

hal-01197059 , version 1 (11-09-2015)

Licence

Identifiants

Citer

Henri Vallon, Andrea Cozza, Florian Monsef, Anne-Sophie Chauchat. Time-Reversed Excitation of Reveberation Chambers: Improving Efficiency and Reliability in the Generation of Radiated Stress. IEEE Transactions on Electromagnetic Compatibility, 2016, 99 (00), ⟨10.1109/TEMC.2015.2478420⟩. ⟨hal-01197059⟩