Experiments have been conducted on 2 pilot plants for activated sludge water treatment in extended aeration differing mainly by aeration sequence. Different wastewater supply and oxygenation capacity programs have been tested. Platinum electrode potentials have been recorded in aeration tanks. Purified water quality has been correlated with electrode potential as observed at the end of the aeration steps. Ammonium level decreased when this electrode potential increased while nitrate concentration simultaneously raised. Both curves intercepted at + 375 mV/NHE or rH = 28.
Cette étude a été conduite sur deux pilotes de stations d'épuration à boues activées en aération prolongée soumis à des séquences différentes d'aération. Plusieurs réglages d'alimentation et de capacité d'oxygénation ont été testés. Les potentiels d'électrode de platine immergées dans les bassins d'aération ont été enregistrés en continu. Des corrélations ont été établies entre la qualité de l'eau épurée et le potentiel d'électrode en fin de période d'aération : la concentration en azote ammoniacal décroît lorsque ce potentiel augmente alors que, simultanément, la concentration en nitrates augmente. L'intersection de ces courbes se situe à + 375 rnV/EHN ou rH = 28. Le potentiel d'électrode atteint après un temps d'aération suffisant caractérise un état d'oxydo-réduction de la boue en relation avec son efficacité épuratrice vis-à-vis de l'azote.