The effect of a direct current field on the microparticle charge in the plasma afterglow
Résumé
Residual charges of individual microparticles forming dense clouds were measured in a RF discharge afterglow. Experiments were performed under microgravity conditions on board the International Space Station, which ensured particle levitation inside the gas volume after the plasma switch-off. The distribution of residual charges as well as the spatial distribution of charged particles across the cloud were analyzed by applying a low-frequency voltage to the electrodes and measuring amplitudes of the resulting particle oscillations. Upon "free decharging" conditions, the charge distribution had a sharp peak at zero and was rather symmetric (with charges concentrated between -10e and +10e), yet positively and negatively charged particles were homogeneously distributed over the cloud. However, when decharging evolved in the presence of an external DC field (applied shortly before the plasma switch-off) practically all residual charges were positive. In this case, the overall charge distribution had a sharp peak at about þ15e and was highly asymmetric, while the spatial distribution exhibited a significant charge gradient along the direction of the applied DC field.