Résumé

This paper presents an improvement of the time resolution of the Photoelectric Laser Stimulation technique using the phase of a mode-locked laser as a reference to generate an electrical stimulus for the device under test. This synchronization system was applied to observe signal propagation in an 860 MHz ring oscillator

Domaines

Electronique

Dates et versions

hal-00204571 , version 1 (15-01-2008)

Identifiants

Citer

Alexandre Douin, Vincent Pouget, Magali de Matos, Dean Lewis, Philippe Perdu, et al.. Time resolved imaging using synchronous picosecond Photoelectric Laser Stimulation. Microelectronics Reliability, 2006, 46 (9-11), pp.1514-1519, 10.1016/j.microrel.2006.07.028. ⟨10.1016/j.microrel.2006.07.028⟩. ⟨hal-00204571⟩