Reliability analysis of Fault Tolerant Wind Energy Conversion System with Doubly Fed Induction Generator - Archive ouverte HAL
Communication Dans Un Congrès Année : 2007

Reliability analysis of Fault Tolerant Wind Energy Conversion System with Doubly Fed Induction Generator

Résumé

This paper presents a fault tolerant converter topology for grid connected Wind Energy Conversion System (WECS) with Doubly Fed Induction Generator (DFIG). This topology allows fault detection and hardware compensation of one of the semiconductors or drivers by using isolating and connecting devices. It is based on a unique redundant leg for both back to back converters. The reliability analysis integrating the semiconductor switching is presented with a efficient modelling method based on Markov Chain model. Application results are presented on the WECS.
Fichier non déposé

Dates et versions

hal-00194995 , version 1 (08-12-2007)

Identifiants

  • HAL Id : hal-00194995 , version 1

Citer

Philippe Weber, Philippe Poure, Didier Theilliol, Shahrokh Saadate, Jean-Christophe Ponsart. Reliability analysis of Fault Tolerant Wind Energy Conversion System with Doubly Fed Induction Generator. 5th Workshop on Advanced Control and Diagnosis (ACD 2007), Nov 2007, Grenoble, France. pp.CDROM. ⟨hal-00194995⟩