Standardless quantification of single fluid inclusions using synchrotron radiation induced X-ray fluorescence - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Chemical Geology Année : 2006

Standardless quantification of single fluid inclusions using synchrotron radiation induced X-ray fluorescence

Résumé

Fluid inclusions are studied using synchrotron radiation induced μ-X-ray fluorescence (μ-SR-XRF). We analyse inclusions from the Brusson gold deposit, Italy. Several two-phase (liquid plus gas) inclusions of a single generation are used to compare a new standardless quantification procedure to previously published internal and external standardisation procedures. The three procedures are based on an infinite homogeneous plane layer and the calculations are performed with a non-iterative fundamental parameter method. Results show a good agreement between the average of the calculated concentrations obtained with the three procedures and the corresponding crush-leach analysis. Cl, K, Ca, Fe, Cu, Zn and As crush-leach concentrations are within error bars of the μ-SR-XRF concentration estimates. Br crush-leach content is above μ-SR-XRF estimates. Ti, Cr, Mn, Ni and Pb were detected with μ-SR-XRF technique only. These elements show different concentrations from one inclusion to another, suggesting heterogeneous trapping of tiny, infra-microscopic solid phases. The good correspondence between the results obtained using the three calibration procedures show that accurate standardless quantitative analysis of individual fluid inclusions is achievable. Statistical error calculation of the three procedures shows that the standardless quantification method yields more accurate results than the internal or external standard procedures. Uncertainties on inclusion depths strongly affect calculated light element concentrations (Cl to Ca), whereas Mn and heavier elements concentration estimates are more sensitive to errors on fluid inclusion thickness. Uncertainties of ± 1 μm or less on fluid inclusion thickness and depth yield statistical errors of not, vert, similar 50% on Cl concentration estimates and lower than 20% on transition metals. This new standardless-μ-SR-XRF based quantification procedure is more precise than the previously established ones and is efficiently applied to multielementary analysis (Cl to Pb) of diluted individual fluid inclusions.

Dates et versions

hal-00149061 , version 1 (24-05-2007)

Identifiants

Citer

Jean Cauzid, Pascal P. Philippot, A. Somogyi, Bénédicte Ménez, A. Simionovici, et al.. Standardless quantification of single fluid inclusions using synchrotron radiation induced X-ray fluorescence. Chemical Geology, 2006, 227 (3-4), pp.165-183. ⟨10.1016/j.chemgeo.2005.09.012⟩. ⟨hal-00149061⟩
73 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More