Pulsed homodyne measurements of femtosecond squeezed pulses generated by single-pass parametric deamplification - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Optics Letters Année : 2004

Pulsed homodyne measurements of femtosecond squeezed pulses generated by single-pass parametric deamplification

Résumé

A new scheme is described for pulsed squeezed light generation using femtosecond pulses parametrically deamplified through a single pass in a thin (0.1mm) potassium niobate KNbO3 crystal, with a significant deamplification of about -3dB. The quantum noise of each individual pulse is registered in the time domain using a single-shot homodyne detection operated with femtosecond pulses and the best squeezed quadrature variance was measured to be 1.87 dB below the shot noise level. Such a scheme provides the basic ressource for time-resolved quantum communication protocols.

Dates et versions

hal-00012423 , version 1 (22-10-2005)

Identifiants

Citer

Jérôme Wenger, Rosa Tualle-Brouri, Philippe Grangier. Pulsed homodyne measurements of femtosecond squeezed pulses generated by single-pass parametric deamplification. Optics Letters, 2004, 29, pp.1267. ⟨hal-00012423⟩