<?xml version="1.0" encoding="utf-8"?>
<TEI xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:hal="http://hal.archives-ouvertes.fr/" xmlns:gml="http://www.opengis.net/gml/3.3/" xmlns:gmlce="http://www.opengis.net/gml/3.3/ce" version="1.1" xsi:schemaLocation="http://www.tei-c.org/ns/1.0 http://api.archives-ouvertes.fr/documents/aofr-sword.xsd">
  <teiHeader>
    <fileDesc>
      <titleStmt>
        <title>HAL TEI export of tel-01147847</title>
      </titleStmt>
      <publicationStmt>
        <distributor>CCSD</distributor>
        <availability status="restricted">
          <licence target="https://creativecommons.org/publicdomain/zero/1.0/">CC0 1.0 - Universal</licence>
        </availability>
        <date when="2026-05-03T19:56:59+02:00"/>
      </publicationStmt>
      <sourceDesc>
        <p part="N">HAL API Platform</p>
      </sourceDesc>
    </fileDesc>
  </teiHeader>
  <text>
    <body>
      <listBibl>
        <biblFull>
          <titleStmt>
            <title xml:lang="en">Modelling and control of synchronous reluctance motor with magnetic saturation effects</title>
            <title xml:lang="fr">Modélisation et commande de la machine synchrone à réluctance variable: prise en compte de la saturation magnétique</title>
            <author role="aut">
              <persName>
                <forename type="first">Thierry</forename>
                <surname>Lubin</surname>
              </persName>
              <email type="md5">af337fb1d2ba3bb69682ccf59b554e5c</email>
              <email type="domain">univ-lorraine.fr</email>
              <idno type="idhal" notation="string">thierry-lubin</idno>
              <idno type="idhal" notation="numeric">3846</idno>
              <idno type="halauthorid" notation="string">2549-3846</idno>
              <idno type="ORCID">https://orcid.org/0000-0002-9449-4130</idno>
              <idno type="IDREF">https://www.idref.fr/072476567</idno>
              <affiliation ref="#struct-407451"/>
            </author>
            <editor role="depositor">
              <persName>
                <forename>Thierry</forename>
                <surname>Lubin</surname>
              </persName>
              <email type="md5">af337fb1d2ba3bb69682ccf59b554e5c</email>
              <email type="domain">univ-lorraine.fr</email>
            </editor>
          </titleStmt>
          <editionStmt>
            <edition n="v1" type="current">
              <date type="whenSubmitted">2015-05-02 09:48:03</date>
              <date type="whenModified">2023-04-25 16:46:48</date>
              <date type="whenReleased">2015-05-04 11:45:59</date>
              <date type="whenProduced">2003-04-18</date>
              <date type="whenEndEmbargoed">2015-05-02</date>
              <ref type="file" target="https://hal.science/tel-01147847v1/document">
                <date notBefore="2015-05-02"/>
              </ref>
              <ref type="file" n="1" target="https://hal.science/tel-01147847v1/file/these_lubin%20%281%29.pdf" id="file-1147847-1230303">
                <date notBefore="2015-05-02"/>
              </ref>
            </edition>
            <respStmt>
              <resp>contributor</resp>
              <name key="158038">
                <persName>
                  <forename>Thierry</forename>
                  <surname>Lubin</surname>
                </persName>
                <email type="md5">af337fb1d2ba3bb69682ccf59b554e5c</email>
                <email type="domain">univ-lorraine.fr</email>
              </name>
            </respStmt>
          </editionStmt>
          <publicationStmt>
            <distributor>CCSD</distributor>
            <idno type="halId">tel-01147847</idno>
            <idno type="halUri">https://hal.science/tel-01147847</idno>
            <idno type="halBibtex">lubin:tel-01147847</idno>
            <idno type="halRefHtml">Energie électrique. Université Henri Poincaré; Nancy I, 2003. Français. &lt;a target="_blank" href="https://www.theses.fr/"&gt;&amp;#x27E8;NNT : &amp;#x27E9;&lt;/a&gt;</idno>
            <idno type="halRef">Energie électrique. Université Henri Poincaré; Nancy I, 2003. Français. &amp;#x27E8;NNT : &amp;#x27E9;</idno>
            <availability status="restricted">
              <licence target="https://about.hal.science/hal-authorisation-v1/">HAL Authorization<ref corresp="#file-1147847-1230303"/></licence>
            </availability>
          </publicationStmt>
          <seriesStmt>
            <idno type="stamp" n="GREEN">Groupe de Recherche en Energie Electrique de Nancy</idno>
            <idno type="stamp" n="UNIV-LORRAINE">Université de Lorraine</idno>
            <idno type="stamp" n="THESES-UL">Thèses de doctorat soutenues à l'Université de Lorraine</idno>
            <idno type="stamp" n="EMPP-UL">Pôle scientifique Energie, Mécanique, Procédés, Produits de l'Université de Lorraine</idno>
          </seriesStmt>
          <notesStmt/>
          <sourceDesc>
            <biblStruct>
              <analytic>
                <title xml:lang="en">Modelling and control of synchronous reluctance motor with magnetic saturation effects</title>
                <title xml:lang="fr">Modélisation et commande de la machine synchrone à réluctance variable: prise en compte de la saturation magnétique</title>
                <author role="aut">
                  <persName>
                    <forename type="first">Thierry</forename>
                    <surname>Lubin</surname>
                  </persName>
                  <email type="md5">af337fb1d2ba3bb69682ccf59b554e5c</email>
                  <email type="domain">univ-lorraine.fr</email>
                  <idno type="idhal" notation="string">thierry-lubin</idno>
                  <idno type="idhal" notation="numeric">3846</idno>
                  <idno type="halauthorid" notation="string">2549-3846</idno>
                  <idno type="ORCID">https://orcid.org/0000-0002-9449-4130</idno>
                  <idno type="IDREF">https://www.idref.fr/072476567</idno>
                  <affiliation ref="#struct-407451"/>
                </author>
              </analytic>
              <monogr>
                <imprint>
                  <date type="dateDefended">2003-04-18</date>
                </imprint>
                <authority type="institution">Université Henri Poincaré; Nancy I</authority>
                <authority type="supervisor">Abderrezak Rezzoug</authority>
                <authority type="supervisor">Hubert Razik</authority>
              </monogr>
            </biblStruct>
          </sourceDesc>
          <profileDesc>
            <langUsage>
              <language ident="fr">French</language>
            </langUsage>
            <textClass>
              <keywords scheme="author">
                <term xml:lang="en">Synchronous reluctance motor</term>
                <term xml:lang="fr">Moteur synchrone à réluctance variable</term>
              </keywords>
              <classCode scheme="halDomain" n="spi.nrj">Engineering Sciences [physics]/Electric power</classCode>
              <classCode scheme="halDomain" n="spi.elec">Engineering Sciences [physics]/Electromagnetism</classCode>
              <classCode scheme="halDomain" n="phys.cond.cm-s">Physics [physics]/Condensed Matter [cond-mat]/Superconductivity [cond-mat.supr-con]</classCode>
              <classCode scheme="halTypology" n="THESE">Theses</classCode>
              <classCode scheme="halOldTypology" n="THESE">Theses</classCode>
              <classCode scheme="halTreeTypology" n="THESE">Theses</classCode>
            </textClass>
            <abstract xml:lang="en">
              <p>This thesis deals with modeling and control of a synchronous reluctance machine. The proposed model takes into account the magnetic saturation. This model is based on the modified Park’s equations. The magnetic saturation is modelled by a single variable coefficient versus all currents flowing in the machine. The model presents the main advantage to have only measurable electrical parameters.The second part is dedicated to the validation of the saturated model. We compared the simulation results with the experimental ones. We studied the case when the machine is connected directly to the network, and when the machine is controlled by vector control. For vector control, we studied the effects of saturation on the dynamics and the steady state conditions. The third part focuses on the development of two control strategies for the steady state operation. The first strategy provides maximum torque for a given current. The control law is derived from the equations of the saturated model. The second strategy is to optimize the performance of the machine. For this, we seek the minimum of power consumption by using optimization algorithms (Fibonacci and golden section). The experimental results showed the feasibility of optimum search online from a system using a DSP (Digital Signal Processor)</p>
            </abstract>
            <abstract xml:lang="fr">
              <p>Ce mémoire porte sur la modélisation et la commande d’une machine synchrone à réluctance variable présentant une cage au rotor. La première partie est consacrée au développement d’un modèle prenant en compte les effets de la saturation magnétique des matériaux. Ce modèle est basé sur une modification des équations de Park. La saturation magnétique est modélisée par un coefficient variable en fonction de l’ensemble des courants circulants dans la machine. Le modèle présente l’avantage de ne faire apparaître que des paramètres électriques mesurables.La deuxième partie est consacrée à la validation du modèle saturé. Pour cela, nous avons comparé des résultats de simulation avec des résultats expérimentaux. Nous avons étudié le cas où la machine est directement reliée au réseau et le cas où la machine est pilotée en commande vectorielle. Dans le cas de la commande vectorielle, nous avons étudié les effets de la saturation sur la dynamique et sur le régime permanent pour une commande en couple et une commande en vitesse. La troisième partie porte sur le développement de deux stratégies de commande pour le régime permanent. La première stratégie permet d’obtenir le couple maximal pour un courant donné. La loi de commande est obtenue à partir des équations du modèle saturé. La deuxième stratégie consiste à optimiser le rendement de la machine. Pour cela, nous recherchons le minimum de la puissance absorbée en utilisant des algorithmes d’optimisation (Fibonacci, section dorée). les résultats expérimentaux ont montré la faisabilité d’une recherche d’optimum en ligne à partir d’un système mettant en œuvre un DSP (Digital Signal Processor)</p>
            </abstract>
          </profileDesc>
        </biblFull>
      </listBibl>
    </body>
    <back>
      <listOrg type="structures">
        <org type="laboratory" xml:id="struct-407451" status="OLD">
          <idno type="IdRef">073908843</idno>
          <idno type="RNSR">200918457C</idno>
          <idno type="IdUnivLorraine">[UL]RQD--</idno>
          <orgName>Groupe de Recherche en Electrotechnique et Electronique de Nancy</orgName>
          <orgName type="acronym">GREEN</orgName>
          <date type="start">2012-01-01</date>
          <date type="end">2017-12-31</date>
          <desc>
            <address>
              <addrLine>Site ENSEM : 2 avenue de la Forêt de Haye, TSA 60604, 54518 Vandoeuvre-lès-Nancy Cedex Site FST : Faculté des Sciences et Technologies, BP 70239, 54506 Vandoeuvre-lès-Nancy Cedex</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://green.univ-lorraine.fr/</ref>
          </desc>
          <listRelation>
            <relation name="EA4366" active="#struct-413289" type="direct"/>
          </listRelation>
        </org>
        <org type="institution" xml:id="struct-413289" status="VALID">
          <idno type="IdRef">157040569</idno>
          <idno type="IdUnivLorraine">[UL]100--</idno>
          <idno type="ROR">https://ror.org/04vfs2w97</idno>
          <orgName>Université de Lorraine</orgName>
          <orgName type="acronym">UL</orgName>
          <date type="start">2012-01-01</date>
          <desc>
            <address>
              <addrLine>34 cours Léopold - CS 25233 - 54052 Nancy cedex</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.univ-lorraine.fr/</ref>
          </desc>
        </org>
      </listOrg>
    </back>
  </text>
</TEI>