<?xml version="1.0" encoding="utf-8"?>
<TEI xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:hal="http://hal.archives-ouvertes.fr/" xmlns:gml="http://www.opengis.net/gml/3.3/" xmlns:gmlce="http://www.opengis.net/gml/3.3/ce" version="1.1" xsi:schemaLocation="http://www.tei-c.org/ns/1.0 http://api.archives-ouvertes.fr/documents/aofr-sword.xsd">
  <teiHeader>
    <fileDesc>
      <titleStmt>
        <title>HAL TEI export of hal-05371230</title>
      </titleStmt>
      <publicationStmt>
        <distributor>CCSD</distributor>
        <availability status="restricted">
          <licence target="https://creativecommons.org/publicdomain/zero/1.0/">CC0 1.0 - Universal</licence>
        </availability>
        <date when="2026-05-15T11:14:08+02:00"/>
      </publicationStmt>
      <sourceDesc>
        <p part="N">HAL API Platform</p>
      </sourceDesc>
    </fileDesc>
  </teiHeader>
  <text>
    <body>
      <listBibl>
        <biblFull>
          <titleStmt>
            <title xml:lang="en">Mass delivery meters using the Coriolis effect for batching hydrocarbon binders</title>
            <title xml:lang="fr">Les débitmètres massiques à effet de Coriolis utilisés avec des liants hydrocarbonés</title>
            <author role="aut">
              <persName>
                <forename type="first">Eric</forename>
                <surname>Chateau</surname>
              </persName>
              <idno type="halauthorid">3895969-0</idno>
              <affiliation ref="#struct-520630"/>
            </author>
            <editor role="depositor">
              <persName>
                <forename>Ifsttar</forename>
                <surname>Cadic</surname>
              </persName>
              <email type="md5">ac6d72b766ba563125152d1789e6a340</email>
              <email type="domain">ifsttar.fr</email>
            </editor>
          </titleStmt>
          <editionStmt>
            <edition n="v1" type="current">
              <date type="whenSubmitted">2025-11-18 15:17:45</date>
              <date type="whenWritten">1991-01-01</date>
              <date type="whenModified">2025-11-20 15:46:47</date>
              <date type="whenReleased">2025-11-18 15:29:38</date>
              <date type="whenProduced">1991-01-01</date>
              <date type="whenEndEmbargoed">2025-11-18</date>
              <ref type="file" target="https://hal.science/hal-05371230v1/document">
                <date notBefore="2025-11-18"/>
              </ref>
              <ref type="file" subtype="greenPublisher" n="1" target="https://hal.science/hal-05371230v1/file/AEP000001956.pdf" id="file-5371230-4594795">
                <date notBefore="2025-11-18"/>
              </ref>
            </edition>
            <respStmt>
              <resp>contributor</resp>
              <name key="128222">
                <persName>
                  <forename>Ifsttar</forename>
                  <surname>Cadic</surname>
                </persName>
                <email type="md5">ac6d72b766ba563125152d1789e6a340</email>
                <email type="domain">ifsttar.fr</email>
              </name>
            </respStmt>
          </editionStmt>
          <publicationStmt>
            <distributor>CCSD</distributor>
            <idno type="halId">hal-05371230</idno>
            <idno type="halUri">https://hal.science/hal-05371230</idno>
            <idno type="halBibtex">chateau:hal-05371230</idno>
            <idno type="halRefHtml">&lt;i&gt;BLPC - Bulletin des Laboratoires des Ponts et Chaussées&lt;/i&gt;, 1991, 175, pp 13-19</idno>
            <idno type="halRef">BLPC - Bulletin des Laboratoires des Ponts et Chaussées, 1991, 175, pp 13-19</idno>
            <availability status="restricted">
              <licence target="https://creativecommons.org/licenses/by-nc-nd/4.0/">CC BY-NC-ND 4.0 - Attribution - Non-commercial use - No Derivative Works<ref corresp="#file-5371230-4594795"/></licence>
            </availability>
          </publicationStmt>
          <seriesStmt>
            <idno type="stamp" n="CEREMA">Centre d'études et d'expertise sur les risques, l'environnement, la mobilité et l'aménagement</idno>
            <idno type="stamp" n="BLPC">Bulletin des Laboratoires des Ponts et Chaussées</idno>
          </seriesStmt>
          <notesStmt>
            <note type="audience" n="1">Not set</note>
            <note type="invited" n="0">No</note>
            <note type="popular" n="0">No</note>
            <note type="peer" n="1">Yes</note>
          </notesStmt>
          <sourceDesc>
            <biblStruct>
              <analytic>
                <title xml:lang="en">Mass delivery meters using the Coriolis effect for batching hydrocarbon binders</title>
                <title xml:lang="fr">Les débitmètres massiques à effet de Coriolis utilisés avec des liants hydrocarbonés</title>
                <author role="aut">
                  <persName>
                    <forename type="first">Eric</forename>
                    <surname>Chateau</surname>
                  </persName>
                  <idno type="halauthorid">3895969-0</idno>
                  <affiliation ref="#struct-520630"/>
                </author>
              </analytic>
              <monogr>
                <idno type="localRef">AEP000001956</idno>
                <idno type="halJournalId" status="INCOMING">1392878</idno>
                <title level="j">BLPC - Bulletin des Laboratoires des Ponts et Chaussées</title>
                <imprint>
                  <biblScope unit="issue">175</biblScope>
                  <biblScope unit="pp">pp 13-19</biblScope>
                  <date type="datePub">1991-01-01</date>
                </imprint>
              </monogr>
            </biblStruct>
          </sourceDesc>
          <profileDesc>
            <langUsage>
              <language ident="fr">French</language>
            </langUsage>
            <textClass>
              <keywords scheme="author">
                <term xml:lang="fr">LIANT HYDROCARBONE</term>
                <term xml:lang="fr">CENTRALE DE FABRICATION</term>
                <term xml:lang="fr">BITUME</term>
                <term xml:lang="fr">ENROBE</term>
                <term xml:lang="fr">DEBIMETRE</term>
              </keywords>
              <classCode scheme="halDomain" n="spi.mat">Engineering Sciences [physics]/Materials</classCode>
              <classCode scheme="halTypology" n="ART">Journal articles</classCode>
              <classCode scheme="halOldTypology" n="ART">Journal articles</classCode>
              <classCode scheme="halTreeTypology" n="ART">Journal articles</classCode>
            </textClass>
            <abstract xml:lang="en">
              <p>The batching of binders in a mixing plant requires an accurate knowledge of the mass delivery of the binder. If we do not know how to measure this, we measure the volume delivery and multiply it by the density. Until about ten years ago, the only mass density measurements were indirect (effects of temperature, impact, etc.) and were not applicable to bitumen. In the late 1970s there appeared a new type of delivery meter using the Coriolis effect and giving a direct measurement of mass delivery. If attention is paid to problems connected with temperature and zero adjustment, these instruments can measure delivery as accurately as the many volume delivery meters currently in use. The advantages of this type of instrument are both technological (there are no moving parts, hence fewer problems due to badly filtered products) and metrologica! (they are independent of parameters such as density, viscosity, pressure and conductivity). These advantages have been verified by tests on four instruments on the SEMR Road Building Equipment Testing Station test bench in Blois.</p>
            </abstract>
            <abstract xml:lang="fr">
              <p>Le dosage du liant sur les centrales d'enrobage nécessite de connaître précisément le débit massique du produit. Ne sachant pas mesurer le débit massique, on mesure un débit volumique que l'on corrige par la densité. Jusqu'à il y a une dizaine d'années, les seules mesures de débit massique étaient des mesures indirectes (effet thermique, effet d'impact...) et n'étaient pas applicables au bitume. A la fin des années 1970, est apparu un nouveau type de débitmètre utilisant l'effet de Coriolis et donnant une mesure directe du débit massique. En restant attentif aux problèmes liés à la température et au réglage du zéro, ces appareils peuvent fournir une mesure de débit aussi précise que celle fournie par les nombreux débitmètres volumétriques utilisés actuellement. Les avantages de ce type d'appareil sont, d'un point de vue technologique, l'absence de mouvement des pièces, donc moins de problèmes mécaniques dus aux produits mal filtrés et, d'un point de vue métrologique, l'indépendance face à des paramètres tels que la densité, la viscosité, la pression et la conductivité. Ces avantages ont été vérifiés par des essais au banc d'essai des éléments de la SEMR de Blois sur quatre appareils.</p>
            </abstract>
          </profileDesc>
        </biblFull>
      </listBibl>
    </body>
    <back>
      <listOrg type="structures">
        <org type="laboratory" xml:id="struct-520630" status="VALID">
          <orgName>Centre d'études techniques de l'équipement Normandie-Centre</orgName>
          <orgName type="acronym">CETE Normandie-Centre</orgName>
          <date type="start">2017-10-24</date>
          <desc>
            <address>
              <addrLine>11 – 13 rue Laplace - CS 32912 - 41029 BLOIS Cedex</addrLine>
              <country key="FR"/>
            </address>
          </desc>
          <listRelation>
            <relation active="#struct-520592" type="direct"/>
          </listRelation>
        </org>
        <org type="institution" xml:id="struct-520592" status="VALID">
          <orgName>Avant création Cerema</orgName>
          <date type="start">2017-10-24</date>
          <desc>
            <address>
              <country key="FR"/>
            </address>
          </desc>
        </org>
      </listOrg>
    </back>
  </text>
</TEI>