Urban Air Quality Management at Low Cost Using Micro Air Sensors: A Case Study from Accra, Ghana - Archive ouverte HAL
Article Dans Une Revue ACS ES&T Air Année : 2024

Urban Air Quality Management at Low Cost Using Micro Air Sensors: A Case Study from Accra, Ghana

Iq Mead
  • Fonction : Auteur
Frederic Coulon
Cesunica Ivey
Garima Raheja
Achim Haug
  • Fonction : Auteur
Anika Krause

Résumé

Urban air quality management is dependent on the availability of local air pollution data. In many major urban centers of Africa, there is limited to nonexistent information on air quality. This is gradually changing in part due to the increasing use of micro air sensors, which have the potential to enable the generation of ground-based air quality data at fine scales for understanding local emission trends. Regional literature on the application of high-resolution data for emission source identification in this region is limited. In this study a micro air sensor was colocated at the Physics Department, University of Ghana, with a reference grade instrument to evaluate its performance for estimating PM2.5 pollution accurately at fine scales and the value of these data in identification of local sources and their behavior over time. For this study, 15 weeks of data at hourly resolution with approximately 2500 data pairs were generated and analyzed (June 1, 2023, to September 15, 2023). For this time period a coefficient of determination (r2) of 0.83 was generated with a mean absolute error (MAE) of 5.44 μg m–3 between the pre local calibration micro air sensor (i.e., out of the box) and the reference-grade instrument. Following currently accepted best practice methods (see, e.g., PAS4023) a domain specific (i.e., local) calibration factor was generated using a multilinear regression model, and when this factor is applied to the micro air sensor data, a reduction, i.e. improvement, in MAE to 1.43 μg m–3 was found. Daily variation was calculated, a receptor model was applied, and time series plots as a function of wind direction were generated, including PM2.5/PM10 ratio scatter and count plots, to explore the utility of this observational approach for local source identification. The 3 data sets were compared (out of the box, domain calibrated, and reference-grade) and it was found that although there were variations in the data reported, source areas highlighted based on these data were similar, with input from local sources such as traffic emissions and biomass burning. As the temporal resolution of observational data associated with these micro air sensors is higher than for reference grade instruments (primarily due to costs and logistics limitations), they have the potential to provide insight into the complex, often hyperlocalized sources associated with urban areas, such as those found in major African cities.
Fichier principal
Vignette du fichier
hodoli-et-al-2024-urban-air-quality-management-at-low-cost-using-micro-air-sensors-a-case-study-from-accra-ghana.pdf (9.6 Mo) Télécharger le fichier
Origine Fichiers éditeurs autorisés sur une archive ouverte

Dates et versions

hal-04831822 , version 1 (12-12-2024)

Licence

Identifiants

Citer

Collins Gameli Hodoli, Iq Mead, Frederic Coulon, Cesunica Ivey, Victoria Owusu Tawiah, et al.. Urban Air Quality Management at Low Cost Using Micro Air Sensors: A Case Study from Accra, Ghana. ACS ES&T Air, 2024, ⟨10.1021/acsestair.4c00172⟩. ⟨hal-04831822⟩
0 Consultations
0 Téléchargements

Altmetric

Partager

More