Active linewidth narrowing of a 8.1µm Quantum cascade laser to a mid-IR frequency comb - Archive ouverte HAL
Proceedings/Recueil Des Communications Année : 2024

Active linewidth narrowing of a 8.1µm Quantum cascade laser to a mid-IR frequency comb

Résumé

In this work we demonstrate a phase-lock of a single-mode continuous-wave Fabry-Perot quantum cascade laser (QCL) emitting at 8.1 μm to a low-noise mid-Infrared (mid-IR) optical frequency comb. The stability of the comb used as a reference is transferred to the QCL resulting in an integrated residual phase error of 0.4 rad. The laser linewidth is narrowed by more than two orders of magnitude reaching 300 Hz at 1ms observation time, limited by the spectral purity of the mid-IR comb.
Fichier principal
Vignette du fichier
2024_Abstract_IRMMWTHz_Active linewidth narrowing of a 8.1µm Quantum cascade laser to a mid-IR frequency comb.pdf (328.33 Ko) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-04805972 , version 1 (26-11-2024)

Identifiants

Citer

Djamal Gacemi, Baptiste Chomet, Olivier Lopez, Livia del Balzo, Angela Vasanelli, et al.. Active linewidth narrowing of a 8.1µm Quantum cascade laser to a mid-IR frequency comb. 2024 49th International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz), IEEE, pp.1-2, 2024, ⟨10.1109/IRMMW-THz60956.2024.10697600⟩. ⟨hal-04805972⟩